Expand your knowledge of hardware, software and supercomputing

Pinpoint a failed drive in your array

If you see that your LSI RAID array has a failed disk, but you’re not sure which physical disk in the machine it is, use the MegaCli command line utility to flash the drive’s LEDs:

Command syntax: MegaCli64 -PdLocate <-start|-stop> -physdrv[<enclosure#>:<disk#>] -a<adapter#>

In this example, we will locate disk 0 on adapter 0 (the first disk in the array):

$ MegaCli64 -PdLocate -start -physdrv[252:0] -a0

Once you’ve found the drive with its activity LED blinking, you can stop it by typing:

$ MegaCli64 -PdLocate -stop -physdrv[252:0] -a0

Use our Breakin stress test and diagnostics tool to pinpoint hardware issues and component failures.
Check out our product catalog and use our Configurator to plan your next system and get a price estimate.

Request a Consultation from our team of HPC and AI Experts

Would you like to speak to one of our HPC or AI experts? We are here to help you. Submit your details, and we'll be in touch shortly.

  • This field is for validation purposes and should be left unchanged.